MGIEasy Exome Capture V4 Probe Set(16 RXN)
Probes |
MGIEasy Exome Capture V4 Probe(16RXN) |
1000007740 |
Hybridization and elution |
MGIEasy MGIEasy Exome Capture Elution Kit(16RXN) |
1000007742 |
特長
Probe regions 59Mb, covering over 20000(refGene)genes The databases used for probe design include CCDS、GENCODE、RefSeq、miRBase and so on. | Deep and comprehensive coverage In HGMD and ClinVar databases, MGIEasy Exome Capture V4 Probe can cover 97% and 85% of mutation sites respectively, playing an important role in disease research and diagnosis. |
Stable and efficient capture rate The capture rate is over 75%. | High consistency rate of variant detection For cell line NA12878,the consistency rate of MGI Probe V4 is 99.2% and 87% for SNV and indels, respectively. |
Compatible with various library preparation methods and sequencing platforms Compatible with MGIEasy Exome Universal Library Prep Kit and MGIEasy Exome FS Library Prep Kit, as well as other library preparation kits. Compatible with sequencing platforms from MGI, Illumina and Thermo Fisher. |
Recommended Applications
Library preparation set | Probes for capture | Compatible sequencing | Read length | Applications |
---|---|---|---|---|
MGIEasy Exome Capture V4 Probe Set | MGIEasy Exome FS Library Prep Set (1000009658) |
BGISEQ-500 MGISEQ-2000 |
PE100/PE150 |
Whole exome sequencing |
MGIEasy Exome Universal Library Prep Set | PE100/PE150 |
Whole exome sequencing |
||
Other library preparation kits | PE100/PE150 |
Whole exome sequencing |
Product Specification
Product name |
MGIEasy Exome Capture V4 Probe Set |
Version | V1.0 |
Packaging (Part number) |
16 RXN (1000007745) |
Probe lenght |
90nt |
Covered region size |
59Mb |
Databasesused for probe design |
CCDS、GENCODE、RefSeq、miRBase |
Covered regions |
Exome regions, >99% disease-related regions |
Storage |
-80℃,-25℃~-18℃,Room temperature(Refer to kit label) |
DNAinput |
1μg PCR product for one sample per hybridization, >250ng each sample for multiple samples per hybridizationand 1μg ≤total input≤2μg |
Number of samples per hybridization |
1-8 |
Sample types |
PCR product |
Compatible species |
Human |
Compatible sequencing platforms |
Platforms from MGI,Illumina and Thermo Fisher |
Read length |
PE100/PE150 |
Detectable mutation types
|
SNV& Indel |
Technologies |
Capture+NGS |
Read length |
PE100/PE150 |
Recommended MGI Process
Applications
|
Library preparation
|
Sequencing
|
Bioinformation analysis
|
---|---|---|---|
|
|
|
Related Documents
- Materials
MGIEasy Exome Capture V4 Probe Set Datasheet Download
1000007745-MGIEasy Exome Capture V4 Probe Set User Manual-A1
This file contains comprehensive information about the product, including detailed operating instructions, reagent supplies and equipment to be used. - SAFETY DATA SHEETS(SDS)